January 6, 2020 by Kevin Stepp

Recovering Energy from Class 2 Exhaust Air

The Problem

Providing a healthy environment must be the top priority for any air conditioning design. This can be difficult though, especially in spaces that generate less-than-ideal breathing conditions. Nail salons, health clubs, and bathrooms are just a few examples of spaces where processes or people taint the air with undesirable chemicals or odors. In these spaces, building designers are missing an opportunity to save valuable energy while providing healthy buildings.

ASHRAE 62.1 – 2019 designates air in these spaces as Class 2 air and stipulates that it must be exhausted. Fresh, but expensive to treat, outside air must be brought into the building to replace the exhaust. Here, designers are dropping the ball if they simply throw away the exhaust air. It contains valuable heat energy that should be recovered and used to reduce the energy needed to condition outside air.

The Solution

Alpha Aire Horizontal and Vertical

United CoolAir’s Alpha Aire utilizes two energy recovery devices to extract heat energy from the exhaust and pre-cool (in summer) and pre-heat (in winter) outside air before it reaches a coil. The unit design reduces the load on the cooling and heating coils to as little as 1/3rd that of a standard outside air unit. At a fraction of the operating cost, Alpha Aire delivers room-neutral (roughly 73° and 50% RH), fresh air to a building.

One common concern with Class 2 applications is whether the exhaust air will be transferred back into the building by way of the energy recovery wheel. United CoolAir utilizes a molecular sieve enthalpy wheel with a rated EATR of 0.5% or less. This means that less than one half of one percent of air leaving the building will be trapped in the wheel and recirculated into the space, a rate undetectable to humans and one far lower than the 10% allowed by ASHRAE 62.1 – 2019.
Designers should not hesitate to use all of the energy at their disposal. Alpha Aire gives them the opportunity to do just that. Call or click the link above to find out more.

Applications

Toilet roomsNail salonsMuseums
Locker roomsPet shopsHotels
Shower roomsBarber shopsHealth clubs
Science labsRestaurantsLaundry rooms
LibrariesBarsPharmacies
Art classroomsBowling alleysChurches

Filed Under: News Tagged With: #hvac, #hvaclife, #hvacquality, #hvacsystem, #hvactechnician

Please follow & like us :)

Follow by Email
Facebook
Facebook
fb-share-icon
Twitter
Visit Us
Tweet
YouTube
LinkedIn
LinkedIn
Share
Get new posts by email
Association Logos

Posts

Recent Posts

  • BTUs in Air Conditioning
  • Commercial vs Residential HVAC
  • Packaged HVAC Indoor vs Outdoor
  • Improving Indoor air hygiene
  • How HVAC Retrofit Can Benefit Commercial Buildings

Calendar

June 2022
M T W T F S S
 12345
6789101112
13141516171819
20212223242526
27282930  
« May    
  • Privacy Policy

UCA Logo

491 E. Princess St.
York, PA 17403
(717) 843-4311
Fax: (717) 854-4462

Please follow & like us :)

Follow by Email
Facebook
Facebook
fb-share-icon
Twitter
Visit Us
Tweet
YouTube
LinkedIn
LinkedIn
Share

Reference LInks

  • Privacy Policy

Site Search

Serial Search

Example

serial no example

© 2022 · United CoolAir, LLC